YASKAWA F7 User Manual page 201

Hide thumbs Also See for F7:
Table of Contents

Advertisement

http://www.aotewell.com
Parameter
Parameter Name
No.
Digital Operator Display
Local/Remote Key
Function
o2-01
Selection
Local/Remote Key
STOP Key Function
o2-02
Selection
Oper STOP Key
User Parameter Default Value
o2-03
User Defaults
Drive/kVA Selection
o2-04
Inverter Model #
Frequency Reference
o2-05
Setting Method Selection
Operator M.O.P.
Operation Selection when
Digital Operator is
o2-06
Disconnected
Oper Detection
Cumulative Operation Time
o2-07
Setting
Elapsed Time Set
Cumulative Operation Time
o2-08
Selection
Elapsed Time Run
Initialization Specification
o2-09
Selection
Init Mode Sel
Cumulative Cooling Fan
o2-10
Operation Time Setting
Fan ON Time Set
Fault Trace/Fault History
o2-12
Clear Function
FLT Trace Init
kWh User Monitor
o2-14
Initialization
kWH MonitorClear
Denotes that parameter can be changed when the Drive is running.
Tel: +(86) 755 8660 6182
Aotewell
Table A.1 F7 Parameter List (Continued)
Description
Key Selections
Determines if the Digital Operator Local/Remote key is
functional.
0: Disabled
1: Enabled
Determines if the STOP key on the Digital Operator will stop the
Drive when Drive is operating from external terminals or serial
communication.
0: Disabled
1: Enabled
Allows storing of parameter settings as a User Initialization
Selection.
0: No Change
1: Set Defaults - Saves current parameter settings as user
initialization. A1-03 now allows selecting <1110> for user
initialization and returns o2-03 to zero.
2: Clear All - Clears the currently saved user initialization. A1-03
no longer allows selecting <1110> and returns o2-03 to zero.
Sets the kVA of the Drive. Enter the number based on Drive model
number. Use the last four digits of the model number.
CIMR-F7U
.
This parameter only needs to be set when installing a new control
board. Do not change for any other reason. Refer to Table B.1.
Determines if the Data/Enter key must be used to input a frequency
reference from the Digital Operator.
0: Disabled - Data/Enter key must be pressed to enter a frequency
reference.
1: Enabled - Data/Enter key is not required. The frequency
reference is adjusted by the up and down arrow keys on the
Digital Operator without having to press the data/enter key.
Determines if the Drive will stop when the Digital Operator is
removed when in LOCAL mode or b1-02=0.
0: Disabled - The Drive will not stop when the Digital Operator is
removed.
1: Enabled - The Drive will fault (OPR) and coast to stop when the
Digital Operator is removed.
Sets the initial value of the elapsed operation timer U1-13.
Sets how time is accumulated for the elapsed operation timer
U1-13.
0: Power-On Time - Time accumulates when the Drive is
powered.
1: Running Time - Time accumulates only when the Drive is
running.
Determines parameter default values after a Drive initialization
(A1-03) is executed. This should always be set to "1" for North
American installations.
1: American spec
WARNING
Possible damage to equipment or injury may occur if this setting is
changed from "1: American Spec." O2-09 is a macro parameter that
can change the default values of terminal I/O and many other
parameters in the drive. Consult the Yaskawa factory for details if
adjustment is required.
Sets the initial value of the heatsink fan operation time monitor
U1-40.
Clears the fault memory contained in the U2 and U3 monitors.
0: Disabled - no effect
1: Enabled - resets U2 and U3 monitors, and returns o2-12 to zero.
Used to reset the kilowatt-hour monitor U1-29 to zero.
0: Disabled - no change
1: Enabled - Resets U1-29 to zero and returns o2-14 to zero.
Parameters A - 36
Aotewell
Email: Sales@aotewell.com
Control Method
Setting
Factory
V/F
Range
Setting
V/F
w/PG
0 to 1
1
A
A
0 to 1
1
A
A
0 to 2
0
A
A
Varies
0 to FF
by
A
A
kVA
0 to 1
0
A
A
0 to 1
1
A
A
0 to
0H
A
A
65535
0 to 1
0
A
A
1
1
A
A
0 to
0H
A
A
65535
0 to 1
0
A
A
0 to 1
0
A
A
http://www.aotewell.com
Open
Flux
Loop
Vector
Vector
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents