Common Specifications - YASKAWA F7 User Manual

Hide thumbs Also See for F7:
Table of Contents

Advertisement

http://www.aotewell.com

Common Specifications

Model Number CIMR-F7U
Rated output capacity
(kVA)
*2
Horsepower
Rated output current (A)
*3
Overload capacity
(% of rated output current
for 60 sec)
Current limit (% of rated
output current)
*5
Carrier frequency
Maximum output
frequency
Rated output capacity
(kVA)
*2
Horsepower
Rated output current (A)
*3
Overload capacity
(% of rated output current
for 60 sec.)
Current limit (% of rated
output current)
*6
Carrier frequency (kHz)
Maximum output
frequency
Maximum output voltage
Rated voltage
Rated frequency
Rated input current -
*1
Heavy Duty
(A)
Rated input current -
*1
Normal Duty
(A)
Allowable voltage fluctuation
Allowable frequency
fluctuation
DC Reactor
Measures for
power supply
harmonics
12-Pulse
Rectification
*1 The difference between Heavy Duty ratings and the Normal Duty ratings for the Drive are the rated input and output current, overload capacity, carrier frequency, current limit, and
maximum output frequency. Parameter C6-01 must be set to value of "0" for Heavy Duty ratings and "2" for Normal Duty ratings. Factory default is Heavy Duty (C6-01=0).
*2 Horsepower ratings are based on 230V or 460V NEC Table 430.150. The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor
.
and Drive, be sure that the Drive's rated output current is appropriate for the motor's rated current.
*3 Model 2110 has an overload rating of 138% of rated output current for 60 seconds and a current limit rating of 138%. Models 4220 and 4300 have an overload rating of 150% of
rated output current for 45 seconds and a current limit rating of 150%.
*4 When setting the carrier frequency above the factory default, the Drive must be derated.
*5 Heavy Duty ratings for models 2110, 4220 and 4300 are effective in software version VSF103021 and higher.
*6 Each value shown is the Maximum carrier frequency and default carrier frequency.
*7 The carrier frequency for Heavy Duty is default to 2 kHz. Software version VSF103021 and higher may allow the carrier frequency to be increased above 2 kHz with a
reduction in continuous rated output current. Refer to C6-02 in Chapter 5 for further details.
Tel: +(86) 755 8660 6182
Table C.2 480Vac Drive Specifications (Continued)
4030
4037
4045
4055
46.0
57.0
69.0
85.0
40
50
60
60.0
75.0
91.0
112.0
51.0
59.0
73.0
95.0
40/50
60
75
100
67.2
77.0
96.0
125.0
107
117
114
108
8
8
8
3-phase, 380, 400, 415, 440, 460 or 480Vac (Proportional to input voltage)
66
83
100
120
74
85
106
134
Specifications C - 4
Aotewell
4075
4090
4110
110.0
140.0
160.0
75
100
125/150
-
150.0
180.0
216.0
150
150
2kHz
300.0Hz
120.0
140.0
180.0
125
150
200
156.0
180.0
240.0
115
120
108
120
5
5
8
5
400.0Hz
3-phase, 380, 400, 415, 440, 460, or 480Vac, 50/60Hz
165
198
238
172
198
264
+ 10%, - 15%
±5%
Built-in
*4
Possible
Aotewell
Email: Sales@aotewell.com
4132
4160
4185
200.0
230.0
280.0
200
250
300
260.0
304.0
370.0
200.0
230.0
315.0
-
250
300/350 400/450
260.0
304.0
414.0
120
120
107
5
5
2
286
334
407
286
334
456
http://www.aotewell.com
4220
4300
315.0
450.0
350
500
414.0
590.0
*3
*3
150
150
*3
*3
150
150
390.0
510.0
500+
515.0
675.0
118
120
2
2
457
649
567
743