C.2

Acquisition Specifications

This section details the acquisition specifications of frequency, data display, and
synchronization (see Table 35 on page 139).
Table 35 Acquisition specifications — OMNI-M-PA32128
Digitizing frequency
A-scan (acquisition
mode)
Maximum pulsing rate
Depth in material
Refresh rate
Envelope (echo-dynamic
mode)
On internal clock
External pace
On encoder
C.3

Data Specifications

This section details the data specifications of processing, TCG, and storage (see
Table 36 on page 139).
Number of data points
Real-time averaging
Rectification
100 MHz (10 bits)
Up to 6000 A-scans per second (512-point,
8-bit A-scan)
Up to 10 kHz (C-scan)
59.8 meters in steel (longitudinal wave),
10 ms with compression
0.49 meters in steel (longitudinal wave),
81.9 µs without compression
A-scan: 60 Hz; S-scan: 20 Hz to 30 Hz
Yes: Volume-corrected S-scan (30 Hz)
Synchronization
1 Hz to 10 kHz
Yes
On 2 axes: from 1 to 65536 steps.
Table 36 Data specifications — OMNI-M-PA32128
Up to 8000.
2, 4, 8, and 16
RF, full wave, half wave+, half wave−
DMTA-20015-01EN [U8778402], Rev. M, February 2017
Frequency
Display
Processing
OMNI-M-PA32128 Module Specifications
139