8.16

Ramp Signal Instruction

Ramp signal
RAMPF
This instruction obtains the data which changes between the start value (initial value) and the end value (target value) over the
specified "n" times.
Ladder diagram
(s1)
(s2)
(d)
FBD/LD
EN
ENO
s1
d
s2
n
Setting data
■Descriptions, ranges, and data types
Operand
Description
(s1)
Initial value of ramp
(s2)
Target value of ramp
(d)
(d)+0: Current value
(d)+1: Number of scans
(n)
Ramp transfer time (scan)
EN
Execution condition
ENO
Execution result
■Applicable devices
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(s1)
(s2)
(d)
(n)
(n)
Word
T, ST, C, D, W,
U\G
SD, SW, R
Structured text
ENO:=RAMPF(EN,s1,s2,n,d);
Range
Data type
16-bit signed binary
16-bit signed binary
16-bit signed binary
1 to 32767
16-bit unsigned binary
Bit
Bit
Double word Indirect
specification
Z
LC
LZ
Data type (label)
ANY16
ANY16
ANY16_ARRAY
(Number of elements: 2)
ANY16_U
BOOL
BOOL
Constant
Others
K, H
E
$