The following figure shows the timing of the receive processing with the SP.SOCRCV instruction.
Open completion signal
OFF
(SD10680.n)
Sequence program
ON
ON
Receive state signal
OFF
OFF
(SD10682.n)
SP.SOCRCV instruction
Completion device (d2)+0
OFF
Completion device (d2)+1
OFF
For details, refer to MELSEC iQ-F FX5 User's Manual (Ethernet Communication).
Operation error
Error code
Description
(SD0/SD8067)
3405H
The connection number specified by (s1) is other than 1 to 8.
2820H
The size of the receive data exceeds the size of the receive data storage device.
The device number specified by (s2), (d1), or (d2) is outside the range of the number of device points.
2822H
Device that cannot be specified is specified.
3582H
When an instruction which cannot be used in interruption routine program is used.
Open
Send
processing
data
ON
END processing
ON
ON
Data
reception
(Only TCP)
Data reading
processing
END processing
END processing END processing
Execute SP.SOCRCV instruction
1 scan
When failed
Data
reading
processing
ACK
10 BUILT-IN ETHERNET FUNCTION INSTRUCTIONS