Download Print this page

Bit Data Interrupt Positioning - Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

16-bit data interrupt positioning

DVIT [For the FX3 compatible operand specification]
This instruction executes interrupt 1-speed constant quantity feed. The high-speed pulse input/output module is not
supported.
Ladder diagram
(s1)
(s2)
(d1)
FBD/LD
EN
ENO
s1
d2
s2
d1
Setting data
■Descriptions, ranges, and data types
Operand
Description
(s1)
Positioning address after an interrupt input
(s2)
Command speed
(d1)
Bit device number (Y) from which pulses are output
(d2)
Bit device number from which the rotation direction is output
EN
Execution condition
ENO
Execution result
■Applicable devices
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(s1)
(s2)
*1
(d1)
*2
(d2)
*1 Only Y can be used.
*2 When the output mode is CW/CCW, specify the CCW axis. When the output mode is PULSE/SIGN and using Y, only the SIGN output or
general-purpose output of the self-axis can be specified.
*3 T, ST, C cannot be used.
(d2)
Word
T, ST, C, D, W,
U\G
SD, SW, R
*3
Structured text
ENO:=DVIT(EN,s1,s2,d1,d2);
Range
Data type
-32768 to +32767
16-bit signed binary
1 to 65535
16-bit unsigned binary
0 to 3
Bit
Bit
Bit
Bit
Double word Indirect
specification
Z
LC
LZ
16.1 Dedicated Instruction (Positioning Function)
Data type (label)
ANY16
ANY16
ANY_ELEMENTARY
(BOOL)
ANY_BOOL
BOOL
BOOL
Constant
K, H
E
$
16 POSITIONING INSTRUCTION
16
Others
847

Hide quick links:

Advertisement

loading