18.30

Converting DINT to REAL

DINT_TO_REAL(_E)
These functions convert DINT type data to REAL type data.
Ladder diagram, FBD/LD
[Without EN/ENO]
s
d
Setting data
■Descriptions, types, and data types
Argument
Description
EN
Execution condition (TRUE: Execution, FALSE: Stop)
s(IN)
Input
ENO
Output status (TRUE: Normal, FALSE: Abnormal)
d(DINT_TO_REAL(_E))
Output
Processing details
■Operation processing
• These functions convert the DINT type data input to (s) to REAL type data and output from (d).
(s)
16543521
DINT
• A value input to (s) is the DINT type data value.
• The number of significant figures of the REAL type data is approximately 7 since the data is processed in 32-bit single
precision.
• The converted data includes an error (rounding error) if an integer value is outside the range of -16777216 to 16777215.
■Operation result
1.
Function without EN/ENO
The operation processing is executed. The operation output value is output from (d).
2.
Function with EN/ENO
The following table lists the execution conditions and operation results.
Execution condition
EN
TRUE (Executes operation)
FALSE (Stops operation)
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
There is no operation error.
[With EN/ENO]
EN
ENO
s
d
(d)
16543521.0
REAL
Operation result
ENO
TRUE
*1
FALSE
Structured text
[Without EN/ENO]
d:=DINT_TO_REAL(s);
[With EN/ENO]
d:=DINT_TO_REAL_E(EN,ENO,s);
Type
Input variable
Input variable
Output variable
Output variable
(d)
Operation output value
Indefinite value
18 TYPE CONVERSION FUNCTIONS
18.30 Converting DINT to REAL
18
Data type
BOOL
DINT
BOOL
REAL