Download Print this page

Transferring 32-Bit Data - Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

Transferring 32-bit data

DMOV(P)
These instructions transfer the 32-bit binary data in the device specified by (s) to the device specified by (d).
Ladder diagram
(s)
FBD/LD
EN
ENO
s
d
Setting data
■Descriptions, ranges, and data types
Operand
Description
(s)
Transfer source data or device number for storing data
(d)
Transfer destination device number
EN
Execution condition
ENO
Execution result
■Applicable devices
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(s)
(d)
Processing details
• These instructions transfer the 32-bit binary data in the device specified by (s) to the device specified by (d).
(s)+1
∙∙∙
b15
(s)
1
0
1
1
(d)+1
∙∙∙
b15
(d)
1
0
1
1
Operation error
There is no operation error.
7 BASIC INSTRUCTIONS
348
7.7 Data Transfer Instructions
(d)
Word
T, ST, C, D, W,
SD, SW, R
∙∙∙
b0
b15
0
1
0
0
0
1
1
∙∙∙
b0
b15
0
1
0
0
0
1
1
Structured text
ENO:=DMOV(EN,s,d);
ENO:=DMOVP(EN,s,d)
Range
-2147483648 to +2147483647
Double word Indirect
U\G
Z
LC
(s)
b0
1
0
0
1
0
(d)
b0
1
0
0
1
0
Data type
32-bit signed binary
32-bit signed binary
Bit
Bit
Constant
specification
LZ
K, H
Data type (label)
ANY32
ANY32
BOOL
BOOL
Others
E
$

Hide quick links:

Advertisement