Download Print this page

Reading Connection Information - Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

Reading connection information

SP.SOCCINF
This instruction reads the connection information.
Ladder diagram
(U)
(s1)
(s2)
FBD/LD
EN
ENO
U0
d
s1
s2
("SP_SOCCINF" enters .)
Setting data
■Descriptions, ranges, and data types
Operand
Description
*1
(U)
Dummy (Input the character string ['U0'].)
(s1)
Connection number
(s2)
Head device number for storing the control data
(d)
Head device number for storing the connection information
EN
Execution condition
ENO
Execution result
*1 In the case of the ST language and the FBD/LD language, U displays as U0.
■Applicable devices
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(U)
(s1)
(s2)
(d)
(d)
Word
T, ST, C, D, W,
U\G
SD, SW, R
Structured text
ENO:=SP_SOCCINF(EN,U0,s1,s2,d);
Range
Data type
Character string
1 to 8
16-bit unsigned binary
Refer to Control data
Word
(Page 750)
Word
Bit
Bit
Double word Indirect
specification
Z
LC
LZ
10 BUILT-IN ETHERNET FUNCTION INSTRUCTIONS
10.2 Socket Communications Function Instructions
Data type (label)
ANYSTRING_SINGLE
ANY16
ANY16_ARRAY
(Number of elements: 2)
ANY16_ARRAY
(Number of elements: 5)
BOOL
BOOL
Constant
Others
(DY)
K, H
E
$
749
10

Hide quick links:

Advertisement

loading