■Control data
Device
Item
(s1)+0
Completion status
(s1)+1
Setting flag
Processing details
• Set the parameters to the FX5-CCLIEF.
[Own station]
FX5 CPU module
CCPASET
• The execution of the G(P).CCPASET instruction and whether it has been completed normally or completed with an error
can be checked with the completion device (d) or completion status indication device (d)+1.
Device
Completion device (d)
Completion status indication device (d)+1
Description
The instruction completion status is stored.
• 0: Normal
• Other than 0: Error (error code)
...
b15
b13 b12 b11 b10 b9 b8 b7
0
(3)
0
(2) (1)
(1) Input setting for data link error (bit 8)
• 0: Cleared
• 1: Held
(2) Output setting for CPU STOP (bit 9)
• 0: Held
• 1: Cleared
(3) Output setting for CPU error (bit 12)
• 0: Cleared
• 1: Held
FX5-CCLIEF
Setting
parameters
Operation
The device turns on during the END processing for the scan in which the G(P).CCPASET instruction is
completed, and turns off during the next END processing.
The device turns on or off depending on the completion status of the G(P).CCPASET instruction.
When completed normally: The device does not change (remains off).
When completed with an error: The device turns on during the END processing for the scan in which the
G(P).CCPASET instruction is completed, and turns off during the next END processing.
Setting range
Shown on left side
...
b0
0
13 CC-LINK IE FIELD NETWORK INSTRUCTION
13.1 Setting parameters
Set by
System
User
13
799