Setting item
Point 3
X coordinate
Y coordinate
Point 4
X coordinate
Y coordinate
Point 5
X coordinate
Y coordinate
Point 6
X coordinate
Y coordinate
Point 7
X coordinate
Y coordinate
Point 8
X coordinate
Y coordinate
Point 9
X coordinate
Y coordinate
Point 10
X coordinate
Y coordinate
Operation error
Error code
Description
(SD0/SD8067)
3405H
The Xn data is not set in the ascending order in the data table.
However, the instructions before the occurrence of an error are executed.
The input value specified by (s1) is out of the range for the set scaling conversion data.
The value in the middle of operation exceeds the 32-bit data range.
In this case, verify that the distance between points is not "65535" or more.
If the distance is "65535" or more, reduce the distance between points.
The number of coordinate points from the device specified by (s2) is 0 or less.
8 APPLICATION INSTRUCTION
566
8.12 Data Control Instruction
Setting device and setting contents
When R0 is specified in (s2)
(s2)+5
R5
(s2)+6
R6
(s2)+7
R7
(s2)+8
R8
(s2)+9
R9
(s2)+10
R10
(s2)+11
R11
(s2)+12
R12
(s2)+13
R13
(s2)+14
R14
(s2)+15
R15
(s2)+16
R16
(s2)+17
R17
(s2)+18
R18
(s2)+19
R19
(s2)+20
R20
Remarks
Setting details
K50
K100
K200
When coordinates are specified using three points in this way,
the output value can be set to an intermediate value.
K25
In this example, the output value (intermediate value) is
K200
specified by the Y coordinate of the point 5.
Even if the X coordinate is the same at three points or more, the
K70
value at the second point is output.
K200
K250
K250
K90
K350
When coordinates are specified using two points in this way, the
output value is the Y coordinate at the next point.
K90
In this example, the output value is specified by the Y
K350
coordinate of the point 9.