Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual page 571

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

Setting item
Setting device and setting contents
When R0 is specified in (s2)
Point 4
X coordinate
(s2)+15, (s2)+14
Y coordinate
(s2)+17, (s2)+16
Point 5
X coordinate
(s2)+19, (s2)+18
Y coordinate
(s2)+21, (s2)+20
Point 6
X coordinate
(s2)+23, (s2)+22
Y coordinate
(s2)+25, (s2)+24
Point 7
X coordinate
(s2)+27, (s2)+26
Y coordinate
(s2)+29, (s2)+28
Point 8
X coordinate
(s2)+31, (s2)+30
Y coordinate
(s2)+33, (s2)+32
Point 9
X coordinate
(s2)+35, (s2)+34
Y coordinate
(s2)+37, (s2)+36
Point 10
X coordinate
(s2)+39, (s2)+38
Y coordinate
(s2)+41, (s2)+40
Operation error
Error code
Description
(SD0/SD8067)
3405H
The Xn data is not set in the ascending order in the data table.
However, the instructions before the occurrence of an error are executed.
The input value specified by (s1) is out of the range for the set scaling conversion data.
The value in the middle of operation exceeds the 32-bit data range.
In this case, verify that the distance between points is not "65535" or more.
If the distance is "65535" or more, reduce the distance between points.
The number of coordinate points from the device specified by (s2) is 0 or less.
Setting details
R15, R14
K200
R17, R16
K25
R19, R18
K200
R21, R20
K70
R23, R22
K200
R25, R24
K250
R27, R26
K250
R29, R28
K90
R31, R30
K350
R33, R32
K90
R35, R34
K350
R37, R36
K30
R39, R38
K400
R41, R40
K7
Remarks
When coordinates are specified using three points in this way,
the output value can be set to an intermediate value.
In this example, the output value (intermediate value) is
specified by the Y coordinate of the point 5.
Even if the X coordinate is the same at three points or more, the
value at the second point is output.
When coordinates are specified using two points in this way, the
output value is the Y coordinate at the next point.
In this example, the output value is specified by the Y
coordinate of the point 9.
8 APPLICATION INSTRUCTION
8.12 Data Control Instruction
8
569