Operation error
• When (s) is REAL
Error code
Description
(SD0/SD8067)
The value specified in (s) is -0, denormalized number, NaN (not a number), or .
3402H
3403H
The value of (d) exceeds the following range. (An overflow has occurred.)
128
|(d)|<2
3405H
Data outside the allowable range was set to (s).
• A negative value is specified.
• "0" is specified.
19 SINGLE NUMBER VARIABLE FUNCTIONS
19.4 Calculating the Common Logarithm
19
979