Processing details
• These instructions divide the BCD 8-digit data specified by (s1) by the BCD 8-digit data specified by (s2), and store the
results of division in the device specified by (d).
(s1)+1
(s1)
5
6
7
8
9
1
2
Quotient
(d)+1
0
0
0
(d)+1, (d)+3
Upper 4 digits
• The results of division are stored as quotient and remainder using 64 bit(s) binary.
• Quotient (BCD 8-digit): Stored in lower 32 bit(s).
• Remainder (BCD 8-digit): Stored in upper 32 bit(s).
• If (d) is specified by bit device, remainder of division results is not stored.
Operation error
Error code
Description
(SD0/SD8067)
2820H
Device specified by (d) exceeds the allowable device range
3400H
0 is specified for (s2) value.
3405H
BCD data in the device specified by (s1) is outside of the valid range (0 to 99999999).
BCD data in the device specified by (s2) is outside of the valid range (0 to 99999999).
(s2)+1
3
÷
0
1
2
3
0 is entered.
(d)
Remainder
0
0
0
4
5
(s2)
4
5
6
7
(d)+3
(d)+2
0
1
2
3
3
6
0
(d), (d)+2
Lower 4 digits