• The table below shows the related devices.
Device
Name
SM700
Carry
SM8020
Zero
SM8021
Borrow
SM8022
Carry
Operation error
Error code
Description
(SD0/SD8067)
3400H
The divisor is 0.
The specified device value is denormalized number, NaN (not a number), or .
3402H
The value stored in specified device is outside the following range
-126
|specified device value|<2
0, 2
Description
Condition
The absolute value of the operation result  2
The operation result is true "0".
(The mantissa part is "0").
The absolute value of the operation result < 2
The absolute value of the operation result  2
128
Operation
128
The value of (d) is the maximum value (2
numbers and the carry flag SM700 turns on.
The zero flag SM8020 turns on.
-126
The value of (d) is the minimum value (2
numbers and the borrow flag SM8021 turns on.
128
The value of (d) is the maximum value (2
numbers and the carry flag SM8022 turns on.
8 APPLICATION INSTRUCTION
8.9 Real Number Instruction
128
) of 32-bit real
-126
) of 32-bit real
128
) of 32-bit real
8