Download Print this page

Setting Annunciator (With Check Time) - Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

Setting annunciator (with check time)

ANS
This instruction sets the annunciator (F device).
Ladder diagram
(s)
(n)
(d)
FBD/LD
EN
ENO
s
d
n
Setting data
■Descriptions, ranges, and data types
Operand
Remarks
(s)
Timer number for evaluation time
(n)
Evaluation time data
(d)
Annunciator device to be set
EN
Execution condition
ENO
Execution result
■Applicable devices
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(s)
(n)
*2
(d)
*1 Only T can be used.
*2 Only F can be used.
Processing details
• This instruction sets (d) when the command input remains ON continuously for the evaluation time [(n)100 ms, (s)] or
more. This instruction resets the current value of (s) evaluation timer and does not set (d) when the command time is less
than the evaluation time [(n)100 ms]. Also, this instruction resets the evaluation timer when the command input turns OFF.
X1
ANS
(s)
(1): Less than the evaluation time ((n)  less than 100 ms)
(2): Equivalent to or longer than the evaluation time ((n)  100 ms or more)
■Related devices
Device
Name
SM8049
ON status annunciator smallest number
enabled
SM8048
Annunciator operation
SD8049
ON status annunciator smallest number
Word
T, ST, C, D, W,
U\G
SD, SW, R
*1
(n)
(d)
Structured text
ENO:=ANS(EN,s,n,d);
Range
Data type
16-bit signed binary
1 to 32767
16-bit unsigned binary
Bit
Bit
Bit
Double word Indirect
specification
Z
LC
LZ
X1
(d)
(1)
(2)
Remarks
When SM8049 is turned ON, SM8048 and SD8049 are enabled.
When one of the F devices is operating, SM8048 turns ON.
The smallest number of the F devices that are operating is stored.
Data type (label)
ANY16
ANY16_U
ANY_BOOL
BOOL
BOOL
Constant
Others
K, H
E
$
6 SEQUENCE INSTRUCTIONS
6.3 Output Instructions
6
129

Hide quick links:

Advertisement

loading