Batch initialization function of extended file register
ERINIT
Initialize all the points of the extended file register (ER) in a batch.
Ladder diagram
(d)
FBD/LD
EN
ENO
d
Setting data
■Descriptions, ranges, and data types
Operand
Description
(d)
Head device number which turns on when the instruction
is completed
When the reading is completed abnormally, (d)+1 turns
on.
EN
Execution condition
ENO
Execution result
■Applicable devices
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(d)
*1 T, ST, C cannot be used.
8 APPLICATION INSTRUCTION
428
8.7 Extended File Register Operation Instruction
Word
T, ST, C, D, W,
U\G
SD, SW, R
*1
Structured text
ENO:=ERINIT(EN,d);
Range
Data type
Bit
Bit
Bit
Double word Indirect
specification
Z
LC
LZ
Data type (label)
ANYBIT_ARRAY
(Number of elements: 2)
BOOL
BOOL
Constant
Others
K,H
E
$