Download Print this page

Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual page 621

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

• The pulse output destination channel number selected on the parameter setting screen can be specified by (d).
• This instruction stores the number of pulses, pulse width, and period output from each channel to an SD device. The pulse
width and period are stored in the units set by the parameters. When 0 is specified in the pulse output, pulses are output
without any limitation.
Pulse output
Number of output pulses
destination channel
CH1
SD5301, SD5300
CH2
SD5317, SD5316
CH3
SD5333, SD5332
CH4
SD5349, SD5348
CH5
SD5365, SD5364
CH6
SD5381, SD5380
CH7
SD5397, SD5396
CH8
SD5413, SD5412
CH9
SD5429, SD5428
CH10
SD5445, SD5444
CH11
SD5461, SD5460
CH12
SD5477, SD5476
Pulse output
ON time
destination channel
CH1
SD5303, SD5302
CH2
SD5319, SD5318
CH3
SD5335, SD5334
CH4
SD5351, SD5350
CH5
SD5367, SD5366
CH6
SD5383, SD5382
CH7
SD5399, SD5398
CH8
SD5415, SD5414
CH9
SD5431, SD5430
CH10
SD5447, SD5446
CH11
SD5463, SD5462
CH12
SD5479, SD5478
Pulse output
Period
destination channel
CH1
SD5305, SD5304
CH2
SD5321, SD5320
CH3
SD5337, SD5336
CH4
SD5353, SD5352
CH5
SD5369, SD5368
CH6
SD5385, SD5384
CH7
SD5401, SD5400
CH8
SD5417, SD5416
CH9
SD5433, SD5432
CH10
SD5449, SD5448
CH11
SD5465, SD5464
CH12
SD5481, SD5480
*1 When the DHCMOV instruction is used, the latest value can be read. A writable device can be updated immediately.
*2 Parameter setting values are set to an SD device at STOP to RUN.
*3 When this instruction is executed, the pulse width and period specified (s1) and (s2) are set to an SD device.
R/W
Initial
Timing of reflection on
value
operation
R/W
0
• When the DHCMOV
instruction is executed
• When the PWM instruction is
executed
• END processing
R/W
Initial
Timing of reflection on
value
operation
*2
R/W
0
• When the DHCMOV
instruction is executed
• When this instruction is
executed
• END processing
R/W
Initial
Timing of reflection on
value
operation
*2
R/W
0
• When the DHCMOV
instruction is executed
• When this instruction is
executed
• END processing
Timing of clearing to initial
value
STOP/PAUSERUN
*1
Timing of clearing to initial
value
STOP/PAUSERUN
*1
*3
Timing of clearing to initial
value
STOP/PAUSERUN
*1
*3
8 APPLICATION INSTRUCTION
8.17 Pulse Related Instruction
8
619

Hide quick links: