Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual page 622

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

• After the pulse output is started from each channel, the pulse output monitor turns on.
Pulse output
destination channel
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
CH11
CH12
• This instruction stores the number of pulses output from each channel.
Pulse output
destination channel
CH1
CH2
CH3
CH4
• The number of output pulses set to an SD device is valid for this instruction as well. The setting values are always read and
updated.
• When the specified number of output pulses is equal to or less than the number of pulses which have already been output,
pulse output stops after outputting pulses which are being output.
• When the specified number of output pulses is larger than the number of pulses which have already been output, pulse
output stops after outputting set number of pulses.
• When the number of output pulses is set from the no limitation output setting (number of output pulses is 0), the number of
output pulses is not updated (because outputting pulses continues or stops in the no limitation output).
• The maximum number of output pulses which can be output when the DPWM instruction is executed once (= maximum
value which can be set to an SD device) is "2147483647"
• The ON time and period can be set during the pulse output. Setting values are always read and updated.
• When the number of output pulses is 0 (no limitation output setting), the monitor of the current number of output pulses is
set to 0.
• When the number of output pulses is specified, the output pulses are monitored. When the DPWM output is executed
several times, the monitor of the number of output pulses is an integrated value.
• The monitor of the current number of output pulses can be changed during the pulse output.
• The monitor of the current number of output pulses is updated when the number of pulses is counted at the falling edge of
pulses in the positive logic and at the rising edge of pulses in the negative logic.
• When the output always remains ON or OFF, the monitor of the current number of output pulses does not change.
• The maximum value of the monitor of the current number of output pulses is "FFFFFFFFH". After the current number of
output pulses reaches the maximum value, the monitor of the current number of output pulses starts to count again from
"0".
8 APPLICATION INSTRUCTION
620
8.17 Pulse Related Instruction
Pulse output monitor
SM5300
SM5301
SM5302
SM5303
SM5304
SM5305
SM5306
SM5307
SM5308
SM5309
SM5310
SM5311
Monitoring the current
number of output pulses
SD5307, SD5306
SD5323, SD5322
SD5339, SD5338
SD5355, SD5354
R/W
Initial
ON timing
value
R
OFF
• When the HIOEN instruction is
executed
• When this instruction is
executed
R/W
Initial
Timing of reflection on
value
operation
R/W
0
• When the DHCMOV
instruction is executed
 An SD device is updated
• When the DPWM instruction is
executed
• END processing
OFF timing
• Power on
• Reset
• RUNSTOP/PAUSE
• When the specified number of
pulses are output.
• The drive contact is turned off
Timing of clearing to initial
value
• Power-on
• Reset
• STOP/PAUSERUN