Download Print this page

Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual page 285

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

• Data specified by (s) can be converted if it is within the range from K0 to K9999 BCD (decimal).
• The table below shows nibble specification for the data in the device specified by (s) and (d).
X0
(s)
(d)
BCD
When "K4Y000" is specified
(d)
K1Y0
K2Y0
K3Y0
K4Y0
Precautions
• Binary data is used in all operations in CPU module including arithmetic operations (+-), increment and decrement
instructions. When receiving digital switch information in binary-coded decimal (BCD) format into a CPU module, use the
BIN(P) instructions (for converting BCD data into binary data). Furthermore, to output data to seven-segment display unit
handling binary-coded decimal (BCD) data, use the BCD(P) instructions (for converting binary data into BCD data).
Operation error
Error code
Description
(SD0/SD8067)
3401H
Data in the device specified by (s) is out of the valid range (0 to 9999).
BIN
CPU module BCD
Y14 to
Y10 to
Y4 to
Y0 to
Y17
Y13
Y7
Y3
BCD
Number of digits
1-digit
2-digit
3-digit
4-digit
Data range
0 to 9
00 to 99
000 to 999
0000 to 9999
7 BASIC INSTRUCTIONS
7.5 Data Conversion Instructions
7
283