Download Print this page

Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual page 856

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

TBL [For the FX5 operand specification]
This instruction executes one specified table operation from the instructions set in the data table using the engineering tool
etc. The high-speed pulse input/output module is not supported.
Ladder diagram
(d)
FBD/LD
EN
ENO
n
d
Setting data
■Descriptions, ranges, and data types
Operand
Description
(d)
Axis number from which pulses are to be output
(n)
Table number to be executed
EN
Execution condition
ENO
Execution result
*1 If the table data is not stored to devices, the table number range is 1 to 32.
■Applicable devices
Operand
Bit
X, Y, M, L, SM,
F, B, SB, S
(d)
(n)
Processing details
This instruction operates one table of the positioning table that is set with parameters in the engineering tool.
• For (d), specify the axis number from which pulses are output.
• For (n), specify the table number to be executed according to the output specified in (d).
For details on the function, precautions, and error code, refer to MELSEC iQ-F FX5 User's Manual (Positioning Control -
CPU module built-in, High-speed pulse input/output module).
16 POSITIONING INSTRUCTION
854
16.1 Dedicated Instruction (Positioning Function)
(n)
Word
T, ST, C, D, W,
SD, SW, R
Structured text
ENO:=TBL(EN,n,d);
Range
K1 to 4
1 to 100
Double word Indirect
U\G
Z
LC
Data type
16-bit unsigned binary
*1
16-bit unsigned binary
Bit
Bit
Constant
specification
LZ
K, H
Data type (label)
ANY_ELEMENTARY
(WORD)
ANY16_U
BOOL
BOOL
Others
E
$

Hide quick links:

Advertisement

loading