Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual page 936

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

■Operation result
1.
Function without EN/ENO
The following table lists the operation results.
Operation result
No operation error occurred
An operation error occurred
2.
Function with EN/ENO
The following table lists the execution conditions and operation results.
Execution condition
EN
TRUE (Executes operation)
FALSE (Stops operation)
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
• When (d) is WORD
Error code
Description
(SD0/SD8067)
3401H
The 32-bit signed binary data in the device specified by (s) is out of the valid range (-32768 to 32767).
Data in the device specified by (s) is out of the valid range (0 to 9999).
• When (d) is DWORD
Error code
Description
(SD0/SD8067)
3401H
Data in the device specified by (s) is out of the valid range (0 to 99999999).
18 TYPE CONVERSION FUNCTIONS
934
18.29 Converting DINT to BCD
(d)
Operation output value
Indefinite value
Operation result
ENO
TRUE (Operation error did not occur)
FALSE (Operation error occurred)
*1
FALSE
(d)
Operation output value
*1
Indefinite value
Indefinite value