Download Print this page

Converting Bool To Time - Mitsubishi Electric MELSEC iQ-F FX5 Programming Manual

Instructions, standard functions/function blocks
Hide thumbs Also See for MELSEC iQ-F FX5:

Advertisement

18.5

Converting BOOL to TIME

BOOL_TO_TIME(_E)
These functions convert BOOL type data to TIME type data.
Ladder diagram, FBD/LD
[Without EN/ENO]
s
d
Setting data
■Descriptions, types, and data types
Argument
EN
s(IN)
ENO
d(BOOL_TO_TIME(_E))
Processing details
■Operation processing
• These functions convert the BOOL type data input to (s) to TIME type data and output from (d).
• When the input value is "FALSE", these functions output 0 as the TIME type data value.
• When the input value is "TRUE", these functions output 1 as the TIME type data value.
(s)
FALSE
TRUE
BOOL
• A value input to (s) is the BOOL type data value.
■Operation result
1.
Function without EN/ENO
The operation processing is executed. The operation output value is output from (d).
2.
Function with EN/ENO
The following table lists the execution conditions and operation results.
Execution condition
EN
TRUE (Executes operation)
FALSE (Stops operation)
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
There is no operation error.
18 TYPE CONVERSION FUNCTIONS
904
18.5 Converting BOOL to TIME
[With EN/ENO]
EN
ENO
s
d
Description
Execution condition (TRUE: Execution, FALSE: Stop)
Input
Output status (TRUE: Normal, FALSE: Abnormal)
Output
(d)
T#1ms
TIME
Operation result
ENO
TRUE
*1
FALSE
Structured text
[Without EN/ENO]
d:=BOOL_TO_TIME(s);
[With EN/ENO]
d:=BOOL_TO_TIME_E(EN,ENO,s);
0
Type
Data type
Input variable
BOOL
Input variable
BOOL
Output variable
BOOL
Output variable
TIME
(d)
Operation output value
Indefinite value

Hide quick links:

Advertisement

loading