Download Print this page

No Clock Timezone - Centrecom FS980M/9 Command Reference Manual

Fs980m series fast ethernet managed access switches reference for alliedware plus version 5.4.6-2.x

Advertisement

S
C
M
YSTEM
ONFIGURATION AND
CLOCK TIMEZONE
clock timezone
Overview
This command defines the device's clock timezone. The timezone is set as a offset
to the UTC.
The no variant of this command resets the system time to UTC.
By default, the system time is set to UTC.
clock timezone <timezone-name> {minus|plus}
Syntax
[<0-13>|<0-12>:<00-59>]

no clock timezone

Mode
Global Configuration
Usage
Configure the timezone before setting the local time. Otherwise, when you change
the timezone, the device applies the new offset to the local time.
Examples
To set the timezone to New Zealand Standard Time with an offset from UTC of +12
hours, use the command:
awplus(config)#
To set the timezone to Indian Standard Time with an offset from UTC of +5:30
hours, use the command:
awplus(config)#
To set the timezone back to UTC with no offsets, use the command:
awplus(config)#
Related
clock set
Commands
clock summer-time date
clock summer-time recurring
613-50137-01 Rev A
C
ONITORING
OMMANDS
Parameter
<timezone-name>
minus orplus
<0-13>
<0-12>:<00-59>
clock timezone NZST plus 12
clock timezone IST plus 5:30
no clock timezone
Command Reference for FS980M Series
AlliedWare Plus™ Operating System - Version 5.4.6-2.x
Description
A description of the timezone, up to 6 characters long.
The direction of offset from UTC. The minus option
indicates that the timezone is behind UTC. The plus option
indicates that the timezone is ahead of UTC.
The offset in hours or from UTC.
The offset in hours or from UTC.