Wave IP 2500 Installation Guide
6CDNG OQWPVKPI VJG 9CXG +2 
Table mounting is a convenient solution for temporary or mobile operation requirements of the
Wave IP 2500. Do not place the Wave IP 2500 on the floor.
Caution:
the Wave IP 2500 chassis, as well as 19 pounds (8.6 kg) additional weight for each EXU that
you are using.
)TQWPFKPI VJG 9CXG +2 
Warning:
permanently connected to earth.
Warning:
have a common ground. If separate grounds are used for telephone and electrical services, a
voltage differential could develop between the two services. This could expose you to an
electrical shock and damage the equipment.
6Q ITQWPF VJG 9CXG +2 
1.
2.
3.
4.

Ensure that the table supports a minimum weight load of 26 pounds (11.8 kg) for
The protective ground lug (earth contact) on the Wave IP 2500 chassis must be
The National Electrical Code requires that the telephone and electrical services
Locate the ground lug on the back of the Wave IP 2500.
Loosen the slotted screw on the ground lug with a flat-head screwdriver.
Insert a 10- or 12-gauge stranded grounding wire into the ground lug opening.
Tighten the slotted screw.