SMC100CC & SMC100PP
EDH0209En2020 – 04/13
2.4.2
Get absolute position.vi
This VI returns the target position value.
Connector Panel
Controls and Indicators
Axis in
Axis out
Target position (units)
2.4.3
Move absolute.vi
This VI allows selecting a target position. This command is only accepted in READY
state. If it is higher or equal to negative software limit and lower or equal to positive
software limit, the controller will move the positioner to the selected target position.
To avoid any mismatch, the controller when it calculates the new target position will
round it to the nearest encoder position.
Connector Panel
Controls and Indicators
Axis in
New target position (units)
Axis out
2.4.4
Get target relative position.vi
This VI returns the target position value.
Connector Panel
Controls and Indicators
Axis in
Axis out
Target position (units)
Single-Axis Motion Controller/Driver for DC or Stepper Motor
44