2.3.5
Set cut off frequency.vi
When the controller is in CONFIGURATION state, this VI sets the low pass filter cut
off frequency value. That is the value that will be used as the setup value for the low
pass filter cut off frequency.
When controller is in DISABLE state, this VI sets the low pass filter cut off frequency
to be used for closed loop.
Connector Panel
Controls and Indicators
Axis in
Cut off frequency value (Hertz)
Axis out
2.3.6
Get following error limit.vi
This VI returns the programmed maximum following error value.
Connector Panel
Controls and Indicators
Axis in
Axis out
Following error limit value (units)