Rexroth EcoDrive Cs Drives
4.3
Ambient and Operating Conditions
Designation
allowed ambient and air inlet
temperature for rated data
maximum allowed ambient and air
inlet temperature with derating
storage and transport temperature
max. allowed installation altitude for
rated data
max. allowed installation altitude
max. allowed relative humidity
allowed degree of contamination
degree of protection
Vibration sinus in operation according
to EN 60068-2-6:
Amplitude and frequency:
Acceleration and frequency:
Tolerance:
Vibration distortion (Random) in
operation according to IEC 68-2-36:
Frequency:
Spectral acceleration density
amplitude:
Tolerance:
Virtual value (r.m.s.) of the
total acceleration:
Compatibility with foreign
matters
DOK-ECODR3-DKC**.3-CS*-PR02-EN-P
Note:
The drive controllers and their additional components are
designed for control cabinet mounting!
Symbol
Unit
T
°C
A
T
°C
A
T
°C
L
m
-
m
-
%
fine dusts not allowed, no moisture condensation
IP20, according to EN 60529 = DIN VDE 0470-1-1992 (IEC 529-1989)
0.15 mm (peak-peak) at 10 ... 57 Hz
1 g at 57 ... 150 Hz
±15 %
20 ... 150 Hz
2
0.005 g
/Hz
± 3 dB
1.0 g
Fig. 4-7:
Ambient and operating conditions
Note:
The user must check that the ambient conditions, in particular
the control cabinet temperature, are complied with by
calculating the heat levels in the control cabinet.
All Rexroth controls and drives are developed and tested according to the
state-of-the-art of technology.
As it is impossible to follow the continuing development of all materials
(e.g. lubricants in machine tools) which may interact with our controls and
drives, it cannot be completely ruled out that any reactions with the
materials used by Bosch Rexroth might occur.
Technical Data (Drive Controllers)
Value
+0 ... +40
+55
-20 ... +80
1000
2000
(max. allowed ambient temperature then is 40 °C
instead of 55 °C)
90
free of moisture condensation
2, according to EN 50178
4-7