Rexroth EcoDrive Cs Drives
Performance Data
DOK-ECODR3-DKC**.3-CS*-PR02-EN-P
Power Balance (Controller and Motor)
P
P
LN
DC
P
2
P
1
P
Diss,Drive
P
:
input power
LN
P
:
DC bus power
DC
P
:
output power of drive controller
OUT
P
:
power at the driven shaft of the motor
mech
P
: power dissipation of drive controller
Diss,Drive
P
: rectifier losses
1
P
: IGBT losses
2
P
: power dissipation of motor
Diss,Motor
P
: brake losses
3
P
: motor losses
4
Fig. 4-9:
Power balance (controller and motor)
The following performance data apply under the following conditions:
• ambient temperature:
• installation altitude:
• The braking resistor installed in the drive controller is not active
(because an external braking resistor is used, for example).
Device type
P
LN
DKCxx.3-0004
165
DKCxx.3-0008
284.5
DKCxx.3-0012
491.6
DKCxx.3-0018
838.1
P
:
input power
LN
P
:
DC bus power
DC
P
:
power dissipation of drive controller and motor
Diss
P
:
power at the driven shaft of the motor
mech
η:
efficiency
Fig. 4-10:
Performance data under rated conditions
Technical Data (Drive Controllers)
P
OUT
P
4
P
3
P
Diss,Motor
40 °C
1000 m
P
P
P
DC
Diss
mech
140.3
64.5
100.5
253.2
83.5
201
457.1
83.4
408.2
796.2
84.5
753.6
4-11
P
mech
leistungsbilanz.fh7
η
60.9
70.6
83
89.9
Need help?
Do you have a question about the EcoDrive Cs and is the answer not in the manual?
Questions and answers