6-20
Mains and Supply Voltage Connection
ext. control voltage +DC 24 V
Emergency stop
Safety limit switch
Power off
Control error
message
Bb 3)
Power on
Power protection
1):
Integrating Bb contacts of more drive controllers in series connection.
(Bb contact: X5_2, Pin 5 and 6);
2):
E-stop for more drive controllers on same contactor.
3):
Switching power of Bb contact must be noted.
Fig. 6-21: Example of generating the E-stop signal
Note:
Do not pick off the E-Stop signal after the Bb contact.
If the safety end switches illustrated also function as a travel
range limit, then a separate set-up must be created in case of
actuation, which makes it possible to move back out of the
end position!
=>
See also Functional Description of firmware: "Travel
range limits".
Rexroth EcoDrive Cs Drives
X5_2/5
X5_1/6
X5_2/6
2)
E- Stop
1)
K1
K1
e_stop_schaltung.FH7
DOK-ECODR3-DKC**.3-CS*-PR02-EN-P