9.5.10

Connecting to AG500

■1. Communication settings
Make the communication settings by operating the key of the temperature controller.
Item
*1
Communication speed
Communication protocol
*1
Data bit configuration
(Data bit, Parity bit, Stop bit)
*2
Device address
(Slave address)
*3
Interval time
*1
Adjust the settings with GOT settings.
*2
Select the device address1 without overlapping with that of other units.
*3
Set the maximum time from the sending of the last character stop bit from the GOT side until the switching of the GOT side to the
receiving status (until the temperature controller becomes ready to send). Set as necessary.
*4
When the setting value is set to 0, a communication is not made.
9.5.11
Connecting to RMC500
■1. Communication settings
Make the communication settings by operating the key of the temperature controller.
Item
*1
Communication speed
Communication protocol
*2
MODBUS data
Extension time
*1
Data bit configuration
(Data bit, Parity bit, Stop bit)
*3
Device address
(Slave address)
*5
Interval time
*1
Adjust the settings with GOT settings.
*2
Set the extension time for the data interval time in the MODBUS communication (which is lower than 24 bit time). Set when the
data time interval exceeds 24 bit time.
*3
Select the device address without overlapping with that of other units.
*4
When the setting value is set to 0, a communication is not made.
*5
Set the maximum time from the sending of the last character stop bit from the GOT side until the switching of the GOT side to the
receiving status (until the temperature controller becomes ready to send). Set as necessary.
9600bps, 19200bps, 38400bps
MODBUS
[8N1]: 8bit, None, 1bit
[8N2]: 8bit, None, 2bit
[8E1]: 8bit, Even, 1bit
[8E2]: 8bit, Even, 2bit
[8O1]: 8bit, Odd, 1bit
[8O2]: 8bit, Odd, 2bit
*4
1 to 99
0 to 250 (ms)
9600bps, 19200bps, 38400bps
MODBUS
0 to 255 (ms)
[8N1]: 8bit, None, 1bit
[8N2]: 8bit, None, 2bit
[8E1]: 8bit, Even, 1bit
[8E2]: 8bit, Even, 2bit
[8O1]: 8bit, Odd, 1bit
[8O2]: 8bit, Odd, 2bit
*4
1 to 99
0 to 250 (ms)
9.5 Temperature Controller Side Setting
Setting range
Setting range