(d)
Setting of Transmission speed, Stop bit, Data bit, Parity bit, Initializing method
Make the settings using the character configuration switches.
Setting item
Transmission speed
Stop bit
Data bit
Parity bit
Initializing method
■3. Connecting to FFU120B
(1) Communication settings
Make the communication settings using setting switches.
MODE
Transmission speed
*1
Data bit
*1
Parity bit
*1
Stop bit
Initializing method
*1*2
Station No.
Terminating resistor
*1
*2
*3
4 - 24
4.2 Serial connection
Set value
9600bps
19200bps
1bit
2bits
7bits
8bits
Even
Odd
Done
None
By switch
Item
*1
*3
Adjust the settings with GOT settings.
Avoid duplication of the station No. with any of the other units.
Turn ON the terminating switch of a general-purpose interface module which will be a terminal.
1
2
ON
OFF
OFF
ON
Command-setting-type start-stop synchronization, nonsequence format
9600bps, 19200bps
8bits or 7bits
Even or Odd
Done, None
1bit, 2bits
By switch
0 to 99
ON or OFF
Switch No.
3
4
5
ON
ON
ON
OFF
ON
OFF
Set value
6
7
8
ON
OFF
ON
OFF
ON

Advertisement