■4. Ethernet setting
Item
Host
Net No.
*2
Station
Unit Type
*1
IP address
Port No.
Communication format
*1
*2
6 - 28
6.3 Ethernet Connection
The host is displayed. (The host is indicated with an asterisk (*).)
Set the network No. of the connected Ethernet module.
(Default: blank)
Set the station No. of the connected Ethernet module.
(Default: blank)
YASKAWA (fixed)
Set the IP address of the connected Ethernet module.
(Default: blank)
Set the port No. of the connected Ethernet module.
(Default: 10500)
Select a communication protocol.
(Default: UDP)
Connection with the PLC is unavailable if the IP address is the default value. Set the value to the IP address of the PLC to be
connected.
Each of [GOT Station] set in the communication detail setting and [Station] set in the Ethernet setting must be set to different
station numbers.
➠ ■2.
Communication detail settings
POINT
POINT
POINT
Ethernet setting for GT21 and GS
(1) Effective range of the Ethernet setting
Only [1] to [4] of the Ethernet setting can be used for the GT21 and the GS. Even though [5]
or later of the Ethernet setting is written to the GT21 and the GS, the setting is disabled on
the GT21 and the GS side.
(2) Range of the host station setting
Set a host station within the range of [1] to [4] of the Ethernet setting.
Only [1] to [4]
can be used.
Description
Set value
1 to 239
1 to 64
YASKAWA (fixed)
PLC side IP address
256 to 65534
UDP, TCP