3.6
Device Range that Can Be Set
The device ranges of controller that can be used for GOT are as follows.
Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.
The device specifications of controllers may differ depending on the models, even though belonging to the same series.
Please make the setting according to the specifications of the controller actually used.
When a non-existent device or a device number outside the range is set, other objects with correct device settings may not
be monitored.
■1. Setting item
Item
*1
Device
Information
*1
The uppermost bit is b0 and the lowermost bit is b15.
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of word device.
Displays the device type and setting range which are selected in [Device].
POINT
POINT
POINT
Device settings of HITACHI PLC
(1) When setting a bit device
Set the device using the format of address (word unit) + bit number (0 to F).
Device name
(2) When setting a word device
For external input (XW), external output (YW), internal register (RW), extended internal
register (MW, AW), keep relay (KW), on-delay timer (TW), one-shot timer (UW), up-down
counter (CW), global link register (GW), event register (EW), system register (SW), transfer
register (JW), and receive register (QW), set as follows.
Device name
Information
Bit position (0 to F)
Address (word units)
Fixed to 0
Address (word units)
3.6 Device Range that Can Be Set