(2) Settings by switch
Make the communication settings using each setting switch.
(a)
Setting of the MODE
Make the MODE settings using the MODE switch.
Command-setting-type start-stop synchronization, nonsequence format
RS-232C 1:1
Command-setting-type start-stop synchronization, nonsequence format
RS-232C 1:1,
and RS-485 1:N
Command-setting-type start-stop synchronization, nonsequence format
RS-485 1:N
(b)
Setting of the station No.
Make the station No. using RS-485 station No. switches.
(c)
Connecting terminating resistors
Turn ON/OFF the terminating resistor using RS-485 terminating resistor ON/OFF switch.
Character configuration
switches
Baudrate setting switch
MODE switch
T-link channel switch
T-link terminating resistor
ON/OFF switch
MODE
RS-485 terminating resistor
ON/OFF switch
RS-485 station No.
switches
Station No.
0 to 99
ON
4.2 Serial connection
Switch position
1
2
3
4 - 27