YASKAWA SGD7S series Product Manual page 204

Servopack with ft/ex specification for tracking application
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

Parameter
Name
No.
Input Signal Selections
2
4
/ZCLAMP (Zero Clamping Input) Signal Allocation

n.
X
Pn50D
/INHIBIT (Reference Pulse Inhibit Input) Signal Allocation

n.
X
/G-SEL (Gain Selection Input) Signal Allocation

n.
X
/P-DET (Polarity Detection Input) Signal Allocation

n.X
5.1 SERVOPACKs with Analog Voltage/Pulse Train References
Setting
Setting
Range
Unit
0000 to
FFFF
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
The allocations are the same as the /ZCLAMP (Zero Clamping
0 to F
Input) signal allocations.
The allocations are the same as the /ZCLAMP (Zero Clamping
0 to F
Input) signal allocations.
The allocations are the same as the /ZCLAMP (Zero Clamping
0 to F
Input) signal allocations.
Continued from previous page.
Default
Applicable
Setting
Motors
Enabled
8888
5.1.2 List of Parameters
When
Classi-
Refer-
fication
ence
After
*1
Setup
restart
Applicable
Motors
All
Applicable
Motors
All
Applicable
Motors
All
Applicable
Motors
Linear
Continued on next page.
5-27
5