Alarm Number:
Possible Cause
Alarm Name
The linear encoder
signal level is too low.
The count-up direc-
tion of the linear
A.C20:
encoder does not
Phase Detection
match the forward
Error
direction of the Mov-
ing Coil in the motor.
The polarity sensor
signal is being
affected by noise.
The polarity sensor is
protruding from the
Magnetic Way of the
motor.
The setting of Pn282
A.C21:
(Linear Encoder Scale
Polarity Sensor
Pitch) is not correct.
Error
The polarity sensor is
not wired correctly.
The polarity sensor
failed.
The SERVOPACK
A.C22:
phase information is
Phase Informa-
different from the lin-
tion Disagree-
ear encoder phase
ment
information.
4.1 SERVOPACKs with Analog Voltage/Pulse Train References
Confirmation
Fine-tune the mounting of
Check the voltage of
the scale head. Or,
the linear encoder sig-
replace the linear
nal.
encoder.
Check the setting of
Pn080 = n.X
Change the setting of
(Motor Phase Sequence
Pn080 = n.X.
Selection). Check the
Correctly reinstall the lin-
installation orientation
ear encoder or Moving
for the linear encoder
Coil.
and Moving Coil.
Correct the FG wiring.
Implement countermea-
sures against noise for the
polarity sensor wiring.
Correctly reinstall the
Check the polarity sen-
Moving Coil or Magnetic
sor.
Way of the motor.
Check the setting of
Check the specifications
Pn282 (Linear Encoder
of the linear encoder and
Scale Pitch).
set a correct value.
Check the wiring of the
Correct the wiring of the
polarity sensor.
polarity sensor.
Replace the polarity sen-
sor.
Perform polarity detec-
tion.
4.1.3 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
*1
*1
*1
Continued on next page.