YASKAWA SGD7S series Product Manual page 127

Servopack with ft/ex specification for tracking application
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

Alarm
Alarm Name
Number
A.d30
Position Data Overflow
MECHATROLINK Internal
A.E02
Synchronization Error 1
MECHATROLINK Trans-
A.E40
mission Cycle Setting
Error
MECHATROLINK Commu-
A.E41
nications Data Size Set-
ting Error
MECHATROLINK Station
A.E42
Address Setting Error
MECHATROLINK Syn-
A.E50*
chronization Error
MECHATROLINK Syn-
A.E51
chronization Failed
Reception Error in
A.E60*
MECHATROLINK Commu-
nications
Synchronization Interval
A.E61
Error in MECHATROLINK
Transmission Cycle
MECHATROLINK Syn-
A.E63
chronization Frame Not
Received
Safety Option Module
A.E71
Detection Failure
Feedback Option Module
A.E72
Detection Failure
Unsupported Safety
A.E74
Option Module
Safety Function Signal
A.Eb1
Input Timing Error
A.EC8
Gate Drive Error 1
A.EC9
Gate Drive Error 2
Command Execution Tim-
A.Ed1
eout
Power Supply Line Open
A.F10
Phase
Servomotor Main Circuit
A.F50
Cable Disconnection
FL-1*
FL-2*
FL-3*
System Alarm
FL-4*
FL-5*
4.2 SERVOPACKs with MECHATROLINK-III Communications References
Alarm Meaning
The position feedback data exceeded
±1,879,048,192.
A synchronization error occurred during MECHA-
TROLINK communications with the SERVO-
PACK.
The setting of the MECHATROLINK communica-
tions transmission cycle is not correct.
The setting of the MECHATROLINK communica-
tions data size is not correct.
The setting of the MECHATROLINK station
address is not correct.
A synchronization error occurred during MECHA-
TROLINK communications.
Synchronization failed during MECHATROLINK
communications.
Communications errors occurred continuously
during MECHATROLINK communications.
An error occurred in the transmission cycle
during MECHATROLINK communications.
Synchronization frames were continuously not
received during MECHATROLINK communica-
tions.
Detection of the Safety Option Module failed.
Detection of the Feedback Option Module failed.
An unsupported Safety Option Module was con-
nected.
An error occurred in the input timing of the safety
function signal.
An error occurred in the gate drive circuit.
An error occurred in the gate drive circuit.
A timeout error occurred for a MECHATROLINK
command.
The voltage was low for more than one second
for phase R, S, or T when the main power supply
was ON.
The Servomotor did not operate or power was
not supplied to the Servomotor even though the
SV_ON (Servo ON) command was input when the
Servomotor was ready to receive it.
An internal program error occurred in the SER-
VOPACK.
4.2.2 List of Alarms
Continued from previous page.
Servo-
Alarm
motor
Reset
Stop-
Possi-
ping
ble?
Method
Gr.1
No
Gr.1
Yes
Gr.2
Yes
Gr.2
Yes
Gr.2
No
Gr.2
Yes
Gr.2
Yes
Gr.2
Yes
Gr.2
Yes
Gr.2
Yes
Gr.1
No
Gr.1
No
Gr.1
No
Gr.1
No
Gr.1
No
Gr.1
No
Gr.2
Yes
Gr.2
Yes
Gr.1
Yes
No
Continued on next page.
4
4-59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents