YASKAWA SGD7S series Product Manual page 188

Servopack with ft/ex specification for tracking application
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

Parameter
Name
No.
Σ-V Compatible Func-
2
tion Switch

n.
X
Reserved parameter (Do not change.)
Encoder Resolution Compatibility Selection
Pn040

n.
X

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections 80
Polarity Sensor Selection

n.
X
Motor Phase Sequence Selection
Pn080

n.
X

n.
X
Reserved parameter (Do not change.)
Calculation Method for Maximum Speed or Encoder Output Pulses

n.X
Application Function
2
Selections 81
Phase-C Pulse Output Selection

n.
X
Pn081

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Pn100
2
Speed Loop Gain
Speed Loop Integral
Pn101
2
Time Constant
Pn102
2
Position Loop Gain
Pn103
2
Moment of Inertia Ratio
Second Speed Loop
Pn104
2
Gain
Second Speed Loop
Pn105
2
Integral Time Constant
Second Position Loop
Pn106
2
Gain
5.1 SERVOPACKs with Analog Voltage/Pulse Train References
Setting
Setting
Range
Unit
0000 to
2111
0
Use the encoder resolution of the connected motor.
Use a resolution of 20 bits when connected to an SGM7J,
1
SGM7A, SGM7P, or SGM7G Servomotor.
0000 to
1111
0
Use polarity sensor.
1
Do not use polarity sensor.
0
Set a phase-A lead as a phase sequence of U, V, and W.
1
Set a phase-B lead as a phase sequence of U, V, and W.
0
Calculate the encoder output pulse setting for a fixed maximum speed.
1
Calculate the maximum speed for a fixed encoder output pulse setting.
0000 to
1111
0
Output phase-C pulses only in the forward direction.
1
Output phase-C pulses in both the forward and reverse directions.
10 to 20,000
0.1 Hz
15 to 51,200 0.01 ms
10 to 20,000
0.1/s
0 to 20,000
1%
10 to 20,000
0.1 Hz
15 to 51,200 0.01 ms
10 to 20,000
0.1/s
5.1.2 List of Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
0000
restart
After
0000
Linear
restart
After
0000
All
restart
Immedi-
400
All
ately
Immedi-
2000
All
ately
Immedi-
400
All
ately
Immedi-
100
All
ately
Immedi-
400
All
ately
Immedi-
2000
All
ately
Immedi-
400
All
ately
Continued on next page.
Classi-
Refer-
fication
ence
Setup
Applicable
Motors
Rotary
*1
Setup
*1
Setup
*1
Tuning
*1
Tuning
*1
Tuning
*1
Tuning
*1
Tuning
*1
Tuning
*1
Tuning
5
5-11