YASKAWA SGD7S series Product Manual page 137

Servopack with ft/ex specification for tracking application
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

Alarm Number:
Possible Cause
Alarm Name
The regenerative
resistor was discon-
nected when the
SERVOPACK power
supply voltage was
high.
DC power was sup-
plied when an AC
power supply input
was specified in the
settings.
A.330:
AC power was sup-
Main Circuit
plied when a DC
Power Supply
power supply input
Wiring Error
was specified in the
(Detected when
settings.
the main circuit
power supply is
Pn600 (Regenerative
turned ON.)
Resistor Capacity) is
not set to 0 and an
External Regenerative
Resistor is not con-
nected to one of the
following SERVO-
PACKs: SGD7S-
R70A, SGD7S-
R90A,SGD7S-1R6A,
or SGD7S-2R8A.
A failure occurred in
the SERVOPACK.
4.2 SERVOPACKs with MECHATROLINK-III Communications References
Confirmation
Measure the resistance
of the regenerative
resistor using a measur-
ing instrument.
Check the power sup-
ply to see if it is a DC
power supply.
Check the power sup-
ply to see if it is an AC
power supply.
Check it see if an Exter-
nal Regenerative Resis-
tor is connected and
check the setting of
Pn600.
4.2.3 Troubleshooting Alarms
Continued from previous page.
Correction
If you are using the regen-
erative resistor built into
the SERVOPACK, replace
the SERVOPACK.
If you are using an Exter-
nal Regenerative Resis-
tor, replace the External
Regenerative Resistor.
Correct the power supply
setting to match the
actual power supply.
Correct the power supply
setting to match the
actual power supply.
Connect an External
Regenerative Resistor, or
if an External Regenera-
tive Resistor is not
required, set Pn600 to 0.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
Continued on next page.
Reference
*1
*1
*1
4
4-69