YASKAWA SGD7S series Product Manual page 186

Servopack with ft/ex specification for tracking application
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

Parameter
Name
No.
Application Function
2
Selections A
Motor Stopping Method for Group 2 Alarms

n.
X
Pn00A
Stopping Method for Forced Stops

n.
X

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections B
Operator Parameter Display Selection

n.
X
Motor Stopping Method for Group 2 Alarms
Pn00B

n.
X
Power Input Selection for Three-phase SERVOPACK

n.
X

n.X
Reserved parameter (Do not change.)
5.1 SERVOPACKs with Analog Voltage/Pulse Train References
Setting
Setting
Range
Unit
0000 to
0044
Apply the dynamic brake or coast the motor to a stop (use the stopping
0
method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
1
torque. Use the setting of Pn001 = n.X for the status after stopping.
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
2
torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in Pn30A. Use
3
the setting of Pn001 = n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in Pn30A and
4
then let the motor coast.
Apply the dynamic brake or coast the motor to a stop (use the stopping
0
method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
1
torque. Use the setting of Pn001 = n.X for the status after stopping.
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
2
torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in Pn30A. Use
3
the setting of Pn001 = n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in Pn30A and
4
then let the motor coast.
0000 to
1121
0
Display only setup parameters.
1
Display all parameters.
0
Stop the motor by setting the speed reference to 0.
Apply the dynamic brake or coast the motor to a stop (use the stopping
1
method set in Pn001 = n.X).
2
Set the stopping method with Pn00A = n.X.
0
Use a three-phase power supply input.
1
Use a three-phase power supply input as a single-phase power supply input.
5.1.2 List of Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
0001
All
restart
After
0000
All
restart
Continued on next page.