YASKAWA SGD7S series Product Manual page 202

Servopack with ft/ex specification for tracking application
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

Parameter
Name
No.
Input Signal Selections
2
2
N-OT (Reverse Drive Prohibit) Signal Allocation

n.
X
/ALM-RST (Alarm Reset) Signal Allocation
Pn50B

n.
X
/P-CL (Forward External Torque Limit Input) Signal Allocation

n.
X
/N-CL (Reverse External Torque Limit Input) Signal Allocation

n.X
5.1 SERVOPACKs with Analog Voltage/Pulse Train References
Setting
Setting
Range
Unit
0000 to
FFFF
0
Enable reverse drive when CN1-40 input signal is ON (closed).
1
Enable reverse drive when CN1-41 input signal is ON (closed).
2
Enable reverse drive when CN1-42 input signal is ON (closed).
3
Enable reverse drive when CN1-43 input signal is ON (closed).
4
Enable reverse drive when CN1-44 input signal is ON (closed).
5
Enable reverse drive when CN1-45 input signal is ON (closed).
6
Enable reverse drive when CN1-46 input signal is ON (closed).
7
Set the signal to always prohibit reverse drive.
8
Set the signal to always enable reverse drive.
9
Enable reverse drive when CN1-40 input signal is OFF (open).
A
Enable reverse drive when CN1-41 input signal is OFF (open).
B
Enable reverse drive when CN1-42 input signal is OFF (open).
C
Enable reverse drive when CN1-43 input signal is OFF (open).
D
Enable reverse drive when CN1-44 input signal is OFF (open).
E
Enable reverse drive when CN1-45 input signal is OFF (open).
F
Enable reverse drive when CN1-46 input signal is OFF (open).
Active on signal edge when CN1-40 input signal changes from OFF (open) to
0
ON (closed).
Active on signal edge when CN1-41 input signal changes from OFF (open) to
1
ON (closed).
Active on signal edge when CN1-42 input signal changes from OFF (open) to
2
ON (closed).
Active on signal edge when CN1-43 input signal changes from OFF (open) to
3
ON (closed).
Active on signal edge when CN1-44 input signal changes from OFF (open) to
4
ON (closed).
Active on signal edge when CN1-45 input signal changes from OFF (open) to
5
ON (closed).
Active on signal edge when CN1-46 input signal changes from OFF (open) to
6
ON (closed).
7
Reserved setting (Do not use.)
8
The signal is always inactive.
Active on signal edge when CN1-40 input signal changes from ON (closed) to
9
OFF (open).
Active on signal edge when CN1-41 input signal changes from ON (closed) to
A
OFF (open).
Active on signal edge when CN1-42 input signal changes from ON (closed) to
B
OFF (open).
Active on signal edge when CN1-43 input signal changes from ON (closed) to
C
OFF (open).
Active on signal edge when CN1-44 input signal changes from ON (closed) to
D
OFF (open).
Active on signal edge when CN1-45 input signal changes from ON (closed) to
E
OFF (open).
Active on signal edge when CN1-46 input signal changes from ON (closed) to
F
OFF (open).
0 to F
The allocations are the same as the /S-ON (Servo ON) signal allocations.
0 to F
The allocations are the same as the /S-ON (Servo ON) signal allocations.
Continued from previous page.
Default
Applicable
Setting
Motors
Enabled
6543
All
5.1.2 List of Parameters
When
Classi-
Refer-
fication
ence
After
*1
Setup
restart
Continued on next page.
5-25