Ricoh MP C2504 Field Service Manual page 1554

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

Category
Code
41
42
40 and larger
43
ID Sensor
44
45
50
51
52
53
54
45 and larger
55
ID Pattern detection
56
57
58
59
90
90 and larger
Result(End)
99
Result name
ID sensor output error (Max)
ID sensor output error (Min)
ID Sensor error (Max)
ID Sensor error (Min)
ID Pattern extract error
Vmin_Bk/K2 error (Max)
Vmin_Bk/K2 error (Min)
K5 error (Max)
K5 error (Min)
K5 calculated approximate point
error
Development gamma error
(Max)
Development gamma error (Min)
Start developing voltage: Vk
error(Max)
Start developing voltage: Vk
error(Min)
Not enough valid data
Potential not adjusted
Stopped
Engine SP Tables - SP3000
Description
Vt > Max
Vt < Min
Development gamma is in target,
but Vt value is less than upper limit.
Development gamma is in target,
but Vt value is less than lower limit.
Cannot detect ID Pattern
K:Vmin_Bk / CMY:K2 > Max
K:Vmin_Bk / CMY:K2 < Min
K5 > Max
K5 < Min
K5 calculated approximate point <
Min
Development gamma > Max
Development gamma < Min
Start developing voltage: Vk >
Max
Start developing voltage: Vk < Min
Adhesion amount data for
development gamma calculation
point is under 2
Potential control method is set as
[0:FIX]
Stopped by door open, power off,
error.
(Set when execute.)