Ricoh MP C2504 Field Service Manual page 1565

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

3. Engine SP Mode Tables
3-232-024 High Coverage Coeff:Y
3-232-040 Initial ProCon Thresh
3-232-041 High Coverage Thresh:H
3-232-050 ProCon Thresh
3-232-060 Low Coverage Thresh
3-232-070 TC Upper Limit Correction
3-232-071 TC Upper Limit:Display:Bk
3-232-072 TC Upper Limit:Display:C
3-232-073 TC Upper Limit:Display:M
3-232-074 TC Upper Limit:Display:Y
3233
[RTP Vtref Corr :Disp/Set]
3-233-001 ON/OFF
3-233-011 Corr Amt(+):K
3-233-012 Corr Amt(+):C
3-233-013 Corr Amt(+):M
3-233-014 Corr Amt(+):Y
3-233-021 Corr Amt(-):K
3-233-022 Corr Amt(-):C
3-233-023 Corr Amt(-):M
3-233-024 Corr Amt(-):Y
3-233-031 Corr Thresh:K
3-233-032 Corr Thresh:C
3-233-033 Corr Thresh:M
3-233-034 Corr Thresh:Y
330
*ENG
[0 to 5 / 1.0 / 0.1/step]
*ENG
[0 to 255 / 100 / 1count/step]
*ENG
[0 to 100 / 100 / 1%/step]
*ENG
[0 to 255 / 100 / 1count/step]
*ENG
[0 to 20 / 3 / 0.1%/step]
*ENG
[0 to 5 / 0.5 / 0.1wt%/step]
*ENG
[1 to 15 / 9 / 0.1wt%/step]
*ENG
[1 to 15 / 9 / 0.1wt%/step]
*ENG
[1 to 15 / 9 / 0.1wt%/step]
*ENG
[1 to 15 / 9 / 0.1wt%/step]
*ENG
[0 to 1 / 1 / 1/step]
*ENG
[0 to 1 / 0.03 / 0.01V/step]
*ENG
[0 to 1 / 0.03 / 0.01V/step]
*ENG
[0 to 1 / 0.03 / 0.01V/step]
*ENG
[0 to 1 / 0.03 / 0.01V/step]
*ENG
[0 to 1 / 0.03 / 0.01V/step]
*ENG
[0 to 1 / 0.03 / 0.01V/step]
*ENG
[0 to 1 / 0.03 / 0.01V/step]
*ENG
[0 to 1 / 0.03 / 0.01V/step]
*ENG
[0 to 0.1 / 0.005 / 0.001mg/cm
step]
*ENG
[0 to 0.1 / 0.01 / 0.001mg/cm
*ENG
[0 to 0.1 / 0.01/ 0.001mg/cm
*ENG
[0 to 0.1 / 0.01 / 0.001mg/cm
2
/
2
/step]
2
/step]
2
/step]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c2004D243D244

Table of Contents