To configure signaling method per port:
1.
Open the Port Ground Start table (Configuration tab > VoIP menu > Media > Port
Ground Start Table).
2.
For each port, select one of the following from the Ground Start drop-down list:
[0] Disable = (Default) Port uses loop-start signaling.
[1] Enable = Port uses ground-start signaling.
3.
Click Submit, and then save ("burn") your settings to flash memory with a device
reset.
14.9

Configuring DSP Templates

The DSP Template determines the coders that can be used by the device and various
other functionalities. For a list of DSP templates and the maximum number of channels
supported by each coder, see 'SBC and DSP Channel Capacity' on page 1139. You can
select a single DSP Template.
Note:
template (i.e., Template 0).
The following procedure describes how to configure a DSP template through the Web
interface. You can also configure it through ini file (DSPVersionTemplateNumber) or CLI
(configure voip > media general > DSP-version-template-number).
To select a DSP Template:
1.
Open the General Settings page (Configuration tab > VoIP menu > Media > General
Media Settings).
Figure 14-14: Defining Single DSP Template in General Settings Page
2.
In the 'DSP Version Template Number' field, enter the required DSP Template
number.
3.
Click Submit, and then reset the device with a burn-to-flash for your settings to take
effect.
User's Manual
Figure 14-13: Port Ground Start Table Page
If you do not configure a DSP template, the device uses the default DSP
Mediant 1000B Gateway and E- SBC
206
Document #: LTRT-27044