Auxiliary And Configuration File Name Parameters - AudioCodes Mediant 1000B User Manual

Media gateway & enterprise session border controller (e-sbc)
Hide thumbs Also See for Mediant 1000B:
Table of Contents

Advertisement

Parameter

59.1.7 Auxiliary and Configuration File Name Parameters

The configuration files (i.e., Auxiliary files) can be loaded to the device using the Web
interface. For loading these files using the ini file, you need to configure these files in the ini
file and configured whether they must be stored in the non-volatile memory. The table
below lists the ini file parameters associated with these Auxiliary files. For more information
on Auxiliary files, see 'Loading Auxiliary Files' on page 715.
Table 59-7: Auxiliary and Configuration File Parameters
Parameter
General Parameters
[SetDefaultOnIniFileProces
s]
[SaveConfiguration]
Auxiliary and Configuration File Name Parameters
Call Progress Tones File
[CallProgressTonesFilenam
e]
Voice Prompts File
[VoicePromptsFileName]
Prerecorded Tones File
[PrerecordedTonesFileNam
e]
User's Manual
Note: For the parameter to take effect, a device reset is required.
Determines if all the device's parameters are set to their defaults
before processing the updated ini file.
[0] = Disable - parameters not included in the downloaded ini file
are not returned to default settings (i.e., retain their current
settings).
[1] = Enable (default).
Note: The parameter is applicable only for automatic HTTP update
or Web ini file upload (not applicable if the ini file is loaded using
BootP).
Determines if the device's configuration (parameters and files) is
saved to flash (non-volatile memory).
[0] = Configuration isn't saved to flash memory.
[1] = (Default) Configuration is saved to flash memory.
Defines the name of the file containing the Call Progress Tones
definitions.
For the ini file, the name must be enclosed by single apostrophes, for
example, 'cpt_us.dat'.
For more information on how to create and load this file, refer to
DConvert Utility User's Guide.
Note: For the parameter to take effect, a device reset is required.
Defines the name of the file containing the Voice Prompts.
For the ini file, the name must be enclosed by single apostrophes, for
example, 'vp_us.dat'.
Note:
For the parameter to take effect, a device reset is required.
For more information on this file, see Voice Prompts File on page
723.
Defines the name of the file containing the Prerecorded Tones.
Note: For the parameter to take effect, a device reset is required.
890
Mediant 1000B Gateway and E- SBC
Description
Description
Document #: LTRT-27044

Advertisement

Table of Contents
loading

Table of Contents