4.2.25 Extension Caller ID [2-11]
Various settings for extension Caller ID can be programmed.
Extension Caller ID Resource-1, 2
Specifies a group of 4 SLT ports that can send Caller ID information to an SLT.
When an extension has this feature activated, there will be a short delay before the extension
rings for incoming calls.
Default
Value Range
Feature Guide References
Feature References
•
Programming References
•
Extension Caller ID Modulation Type
Specifies the modulation frequency to be used when sending Caller ID information to an SLT.
Default
Value Range
Feature Guide References
Feature References
•
Programming References
•
Channel Seizure Signal bits
Specifies the number of seizure bits to send when sending Caller ID information to an SLT.
Default
Value Range
Feature Guide References
Feature References
•
Programming References
•
Mark Signal bits
Specifies the number of mark bits to send when sending Caller ID information to an SLT.
Disable
Disable: No port
Slot 01:HLC4: Initially installed 4 Hybrid ports
Slot nn:SLC8 1-4: Ports 1 to 4 of the SLC8 card (nn=slot number)
Slot nn:SLC8 5-8: Ports 5 to 8 of the SLC8 card (nn=slot number)
1.16.1 Caller ID
4.4.1 Wired Extension—Extension Settings [4-1-1]—Option 7—Extension Caller ID
Bell202(Bellcore)
V.23(ETSI), Bell202(Bellcore)
1.16.1 Caller ID
None
300 bits
10 × n (n=3–40) bits
1.16.1 Caller ID
None
4.2 System [2]
Feature Guide
323