2.
Connection Methods for Remote Programming
Method
Off-site modem Call the PBX and have the call directed to the floating
On-site modem The modem is connected to the Serial Interface (RS-
Conditions
Only one system programming session is permitted at a time. Access will be denied when
a second party tries to perform system programming, including system programming via
a PT.
Programmer Code and Password for System Programming
To access system programming, a programmer code (login ID for the programmer) and its
password must be entered. There are three programmer codes, which are set at the
factory and cannot be changed. Each programmer code has a unique password which is
also set at the factory. These passwords can be changed through system programming. If
the wrong password is entered a preprogrammed number of times during remote (off-site)
Description
extension number assigned to the analog remote
maintenance feature (
Number [811]) using one of the following methods:
Direct Access: Using the off-site modem, dial a
telephone number with the modem which will direct
your call (via Direct In Line [DIL] distribution) to the
floating extension number assigned to the analog
remote maintenance feature.
DISA: Using a telephone, dial a telephone number
which will direct your call (via DIL distribution) to a
floating extension number used by the Direct Inward
System Access (DISA) feature (
Inward System Access (DISA)). Next, dial the floating
extension number assigned to the analog remote
maintenance feature. Then access the PBX with the
modem.
Call Transfer: Using a telephone, dial a telephone
number which will direct your call to an operator (or
other extension of the PBX) and request to be
transferred to the floating extension number assigned
to the analog remote maintenance feature. (
Call Transfer) Then access the PBX with the modem.
232C port) and also to either an extension port which
is assigned as the DIL destination, or to a CO line
directly. AT commands can be sent to the modem
automatically when it is connected to the Serial
Interface (RS-232C port) and can be programmed
beforehand, through system programming, to initialize
the modem. AT commands can also be sent manually
in the PT system programming mode (
Modem Control [801]).