Name
Description
PWR
Power indication
ALRM
Micro Base Station alarm
indication
SP
Spare
EXT ALRM
External alarm indication
WACT
Wireless link activity
indication
WLINK
Wireless link status
indication
ODU 1/ODU 2
ODU power indication
PWR
ODU 1/ODU 2
ODU alarm indication
ALRM
Manual Revision 1.0
Table 2-16: Micro Base Station LEDs
Functionality
Red – Micro Base station failure
Not Used
Red – External alarm (received via the
ALRM IN port). Not applicable in current
release.
IDU-ODU communication failure
Installing the Micro Base Station Equipment
Off – Micro Base Station is not
powered
Red – Input power failure
Green – Micro Base Station power OK
Off – No wireless link activity
Green (blinking) – Wireless link
activity
Off – No SU is connected
Green – At least one SU is connected
Off – ODU not powered
Red – ODU power (-48VDC) failed
Green – ODU power OK
2-33