Smart Mesh Networking Best Practices

Signal Quality Verification

Figure 188. Root Placement
If the customer's network utilizes a wireless backhaul technology for broadband access, it
is recommended to not mount the broadband wireless modem right next to a Ruckus
Wireless AP. A distance of 10 feet or more would be desirable.

Signal Quality Verification

The above guidelines for planning will result in a well-designed mesh. However, it is advisable
to place the APs in the planned locations temporarily using a tripod stand or other means, and
actually checking the Signal Quality throughout the mesh network. In addition, once the mesh
is deployed, the Signal Quality should be periodically monitored to make sure the mesh is
operating optimally. Signal Quality is a measurement of the link quality of the MAP's uplink,
and is available on the ZoneDirector Web interface.
To view the Signal parameter in the Zone Director Web interface, go to Monitor > Access
Points, and click on the Mesh AP being tested (click the MAC address) to see the Access Point
detail screen, as shown in
There are two best practice observations that should be met:
Ensure Signal >= 25%: The Signal value under Neighbor APs that shows "Connected"
should be 25% or better. If it is lower, you need to bring the AP closer, or move it to avoid
an obstruction, such that the Signal value becomes 25% or better. For a more conservative
design, you may use 35% as your Signal benchmark.
Figure 189
below.